How to calibrate the rotation angle sensor by Launch X431 PAD VII
Any of Launch X431 PAD VII, European Euro Tab III, MM4.0 (other devices can buy “Motor Angle Calibration” function in Mall module) can calibrate the rotation angle sensor of the motor for BMW, MINI, Toyota, Lexus, Honda, Acura.
Why it is necessary to calibrate the rotation angle sensor of the motor?
A resolver is a type of rotation angle sensor for controlling the
drive motor that is the power source of EVs. By efficiently controlling
the motor, power consumption can be suppressed. To control the motor
according to various driving conditions of a vehicle, it is necessary to
detect the magnetic pole position of the motor and accurately grasp its
rotational speed. The resolver serves as a sensor for these tasks.
Image 1. Rotation angle sensor (resolver) for EV/HEV electric motor
The speed of the motor that is the heart of the electric vehicle, when the motor is working in a high temperature environment or in a humid, dusty and other environment for a long time, the resolver (rotation angle sensor) is prone to failure. After the failure, the rotation angle sensor signal is faulty, resulting in the motor not working normally, reducing the system reliability, and affecting the normal driving of the vehicle.
At this time, it is necessary to calibrate the rotation angle sensor of the motor.
Motor Angle Calibration Guide with Launch X431
Take Toyota as an example:
1. Enter Motor Angle Calibration V10.00, Click “TOYOTA”.
3. Note “select the vehicle mode menu according to the vehicle model on the nameplate”, and click “OK” to continue.
4. Click “AXXH50”.
5. Click “A25A-FXS”.
6. Confirm the info and click “OK”.
7. If communication abnormality occurs during the test, please ensure
whether the vehicle is equipped with other parts. If other parts are
installed, you can try to remove the parts and then perform the test.
Click “OK” to continue.
9. Notice “this ECU controls the power conversion apparatus for
driving two motors and the voltage conversion device”, click “OK” to
continue.
11. Select the resolver you want to relearn or initialization; here we select “Resolver Learning/Initialization”.
12. This function is used to learn and initialize the correction
amount for resolver variations. Refer to the repair manual when you use
this function. Press “OK” to proceed.
14. The initialization is ready, turn the IG off; after the IG is OFF, follow the instructions in the repair manual.
That’s all, this is how to use any of X-431 Pad VII, European Euro Tab III, MM4.0 to do Motor Angle Calibration.